Solar Panel Current Meter
(C) G. Forrest Cook
1999
Introduction
This circuit is used to measure the current from a solar
panel. It has very low power loss for currents in the 0-10A range. It also works
as a general purpose DC current meter. The circuit can be used on either the
positive or negative side of a DC circuit.
Specifications
Measured Current: 0-10 Amps DC
Circuit Voltage: Will work with DC circuits at any practical voltage.
Accuracy: approximately 2%, depending on the meter movement.
Theory
The current to be measured flows through the 0.01 ohm resistor
which causes a small voltage drop across the resistor. The 100 microamp meter is
set up with the series 50 ohm and 500 ohm variable resistor in a voltage
measurement configuration to measure this voltage drop. The 500 ohm variable
resistor is used to adjust the meter's full scale reading. The 50 ohm resistor
limits the maximum current to the meter no matter what setting is on the 500 ohm
resistor, this protects the meter from passing too much current and burning up.
The series resistance of the meter, 500 ohm (or less) variable resistor and 50
ohm resistor should total 1000 ohms. Different meters may require a different
variable resistor to achieve the 1000 ohm value.
Construction
Build the meter into a metal box with the meter and two
connectors mounted on the outside of the box.
Alignment
Put the meter circuit in series with a known current meter
such as a digital VOM meter set to measure current. Run a known current through
both meters. Adjust the 500 ohm resistor until both meters read the same
current. A good way to get a known current is to put a 12V lead acid battery in
series with a 2 ohm 100 watt current limiting resistor. This will produce
approximately 6 Amps of current. Put the two meters in series with this loop and
adjust for the same reading. Beware, the resistor will get fairly hot in a short
time.
Use
Connect this circuit in series with a nominal 12V or 24V solar panel
array. The meter can go in either the positive or negative side of the solar
panel circuit. The current flowing through the solar panel to the load will be
shown on the meter.
Parts
1x 100 microamp DC meter
1x 0.01 ohm 5 W resistor
1x 50 ohm 1/4 W resistor
1x 500 ohm 10 turn variable resistor
2x banana plugs or a 2 pin screw type terminal block.
1x metal box
Parts Sources
Newark Electronics
Back to FC's Solar
Circuits page.